Current core market: Smart Aquaculture · Farm deployment · Overseas support
SAFEBACK · SAFE SMART ENERGY

Safe Smart Energy for Aquaculture.
We Watch, You Sleep.

SAFEBACK builds safe smart energy technology, with smart aquaculture as its first market: intelligent power, equipment control and energy management for farms — real-time DO monitoring, automated aeration, low-oxygen alerts and multi-pond management. Less manual night patrol. Faster response.

Smart aquaculture pond scene: 4G controller + dissolved oxygen sensor + solar power
7.2 mg/L · DO normal
Smart Aquacultureour first market
Controllers + Sensorscore hardware · self-developed
AI + Platformcore software
Storageavailable as OEM / ODM
SCROLL
ENERGY SECURITY · PAIN POINTS

It Starts with Power Security, Then Smart Aquaculture Gets Truly Smart

Energy safety → electrical safety → intelligent control → smart aquaculture: aerators and pumps run for months non-stop, yet traditional farms have no continuous electrical-safety monitoring or energy data. SAFEBACK closes that gap with sensors, smart controllers, communication and AI.

!

Blackout → Hypoxia → Dead Stock

Summer thunderstorms, typhoon load-shedding or a burnt-out transformer stop the aerators. Between 3 and 5 a.m. dissolved oxygen falls off a cliff, and the whole pond can be lost in hours.

$

Electricity Eats Your Margin

Fixed schedules do not know what the pond needs right now. SAFEBACK uses real-time DO data to support automatic aeration decisions, helping farms operate equipment according to actual pond conditions.

24h

3 a.m. Pond Patrols

However experienced you are, you still get up at night to patrol the pond, look for gasping fish and decide whether to start the aerators. Labour costs money, it exhausts you, and judgement slips.

?

Sensor Drift & Constant Maintenance

Reliable monitoring depends on good sensor maintenance and clear alarms. SAFEBACK combines DO monitoring, device status and alerts so operators can act before a problem becomes critical.

CORE FEATURES

Monitor · Decide · Act — 24/7

SAFEBACK connects dissolved oxygen sensing, aerator control, connectivity, cloud services and mobile monitoring into one practical system for aquaculture farms.

01 · Never Offline

Four Power Layers · Zero Single Point of Failure

From utility grid, battery storage and genset down to a hardware bypass lever: if one layer fails, the next one takes over automatically.

  • Layer 1 — automatic changeover between grid / PV-storage microgrid / genset (the PCS takes over off-grid in milliseconds)
  • Layer 2 — LiFePO4 storage with BMS, 5~20 kWh, expandable
  • Layer 3 — diesel genset as the final backup, ATS linked to the EMS
  • Layer 4 — physical lever-relay bypass; even if every system fails, one flip keeps the power on
02 · Intrinsically Safe

DC 48V SELV · Low-voltage safety design

In accordance with GB/T 3805 / IEC 61140 SELV — essentially harmless to people and to fish.

  • A DC 48V bus replaces part of the AC load; low-voltage design helps reduce electrical safety risks on site
  • Four-level lightning protection: grid-entry SPD / DC bus SPD / board-level / equipotential earthing
  • graded surge protection and equipotential bonding; final withstand levels depend on product selection and testing
  • Latching relay plus lever bypass: state survives power loss, remains remotely readable and controllable
03 · Always Online

3 Links × 3 Chips · Edge-Cloud Unified

4G, Wi-Fi and Bluetooth serve different connectivity scenarios; edge decisions, cloud rules and the mobile app work together.

  • Three links: 4G (remote) / Wi-Fi (pond-side LAN) / BLE (local commissioning)
  • Three chips: 4G modem + ESP32 edge decision + imported 32-bit ARM MCU, each doing its own job
  • Edge DO loop: second-level local decisions, no dependency on cloud round-trips
  • Remote OTA upgrades · rule engine · multi-pond control · mobile management
Depending on site conditions, power options can include grid, storage, genset and local fallback control to improve operational resilience.
THREE-LAYER ARCHITECTURE

Cloud Platform · IoT Layer · Power Layer

SAFEBACK = power distribution + IoT + cloud: a three-tier, coordinated aquaculture operating system. Every tier can run standalone; together they form a thinking "pond brain".

PLATFORM

Cloud Platform

cloud SaaS · O&M · subscription

device onboardingEMQX / MQTT · TLS
time-series storeTDengine · 30-day+ trend curves
rule enginegraded alarms · interlocking
OTAdifferential / A-B zone control
APIcustomer / integrator integration
subscription servicesdata / alerts / O&M / value-added
IOT

IoT Layer

4G controller · sensors · edge loop

4G controllerESP32-S3 + EC600N
DO (dissolved oxygen)fluorescence method, ±0.2 mg/L
auto-cleaningwiper mechanism, drift-free
pH / ammonia4-20 mA analogue
water temp · air pressureDS18B20 + barometer
edge DO loopsecond-level local decisions
POWER

Power Layer

DC 48V microgrid · 380V AC coupling

Route Anative DC 48V (new ponds)
Route B380V PV-storage-genset microgrid (retrofit)
PCSmillisecond off-grid switchover <100 ms
EMSfour-state machine S1-S4
lightning protectionfour-stage SPD + equipotential
latching relayzero holding power, state retained
The 4G controller is the kernel of the aquaculture OS. It pulls sensors, aerators, VFDs, battery storage and genset onto one data bus, closing the loop of "monitoring + decision + interlock" inside a single device.
DUAL ROUTES

Two Technical Routes Covering Every Pond

New ponds adopt a native DC 48V microgrid (Route A); existing 380V sites get PV-storage-genset AC coupling (Route B). The two routes are complementary — never conflicting, never mixed up.

ROUTE A · Native DC

DC 48V Microgrid

new ponds / DC-native architecture / the optimal power topology

  • multi-source input (grid / PV / storage / genset) dispatched onto a single DC 48V bus
  • LiFePO4 storage with BMS, 5~20 kWh, expandable
  • DC 48V SELV low-voltage design; final safety performance depends on product certification and site standards
  • DC-specific SPD plus board-level protection; ±2 kV lightning withstand
  • all-low-voltage copper cabling from cabinet to load; lowest installation cost
Best for:new farms, fibreglass / tarpaulin tanks, recirculating systems and small clustered ponds.
ROUTE B · 380V Retrofit

PV-Storage-Genset AC Coupling

existing 380V ponds / no rewiring / upgrade in place

  • triple-source auto changeover: grid / storage / genset (ATS + EMS)
  • PCS off-grid switchover in milliseconds (<100 ms) - aerators coast through without stopping
  • four-state machine S1-S2-S3-S4 covers every outage scenario
  • keeps the existing 380V three-phase wiring; aerators untouched
  • three revenue streams: peak-valley arbitrage, VFD savings and avoided outage losses
Best for:existing 380V ponds, customers wanting fast payback with no rewiring.
SAFEBACK TECHNOLOGY

Energy Sensors · Smart Controllers · Communication Gateway · Energy AI · Energy Platform

Controllers and sensors are fully self-developed; storage products are available as OEM/ODM — every item backed by engineering, not slides. These technologies are currently applied primarily to smart aquaculture.

Photo · In-house PCB
TK-4G-GW Kantangren 4G Aquaculture Gateway V1, unit photo
Smart Controller · Communication Gateway

TK-4G-GW · 4G Aquaculture Gateway V1

In-house 4G IoT gateway board: 4G IoT SIM + 2 RS485 terminal groups (parallel on one bus) + edge DO loop — one device that pulls sensors, aerators and VFDs onto a single data bus.

  • ModelTK-4G-GW
  • Comms4G IoT SIM · three-chip architecture
  • PortsRS485: 2 terminal groups · 12V output
  • DownloadUSB port · remote OTA
  • Rolepond-side edge decision kernel
Core component · Y504-A
Y504-A fluorescence dissolved-oxygen sensor
Energy Sensor · Water-Quality Sensing

Y504-A Dissolved Oxygen Probe

Y504-A fluorescence-quenching DO probe: no electrolyte, no frequent recalibration, no membrane, IP68 titanium-alloy housing, RS485 Modbus straight into the 4G controller — the drift problem solved at its root.

  • Principlefluorescence quenching · maintenance-free
  • Range0–20 mg/L
  • Ingress ratingIP68 · titanium alloy
  • OutputRS485 Modbus RTU
Photo · In-house PCB
TK-R12-SC4S-BG Kantangren Three-Phase 380V 12-Channel Controller Board V1.0, unit photo
Smart Controller · Power Distribution

TK-R12-SC4S-BG · 12-Channel Controller Board V1.0

Three-phase U/V/W × 4 channels = 12 high-current relay outputs, three-phase 380V input, no neutral required (or one 220 V single-phase unit per pole, up to 12 when the whole site is single-phase, neutral taken from the panel); three RS485 ports plus a 12V bus cascade with the 4G gateway, scalable to 6.7 ha+ clusters.

  • ModelTK-R12-SC4S-BG
  • Output12 channels · three-phase 380V (no neutral)
  • Bus3 × RS485 + 12V
  • Main control32-bit MCU · on-board storage
  • Integrationfits IP55 enclosures · four-stage lightning protection
Core component · VFD
Waterproof VFD
Smart Drive · Energy-Saving Execution

Waterproof VFD

Wall-mounted waterproof VFD driven directly by the 4G controller over RS485 Modbus; DO thresholds map to four automatic speed steps — a further actual energy performance depends on the pond, equipment and operating strategy.

  • ProtocolRS485 Modbus RTU
  • Voltagethree-phase 380V · 0-50 Hz
  • Stepsfour-step DO-to-frequency map
  • SavingsPotential energy savings vary by site
Storage · Rack-mounted
R40KL 40 kWh rack-mounted ESS
Rack-Mounted ESS · OEM/ODM

R40KL · 40kWh

5.12 kWh × 8 = 40.96 kWh of rack modules, 51.2V DC compatible with a 48V bus, fits standard 19-inch cabinets; once connected to the Kantangren 4G controller it charges at off-peak tariff and discharges at peak.

  • Capacity40.96 kWh · 5.12 kWh per module
  • Voltage51.2V DC · 48V bus compatible
  • Form factorrack-mounted · 19-inch cabinet
  • ControlBMS + EMS · 4G remote access
Storage · Outdoor cabinet
S40K 60 kWh outdoor cabinet ESS
Outdoor Cabinet ESS · OEM/ODM

S40K · 60kWh

30.72 kWh × 2 = 61.44 kWh modular lithium storage cabinet, 51.2V DC plug-and-expand straight onto the bus; IP55 rated, >6,000 cycles, BMS + EMS coordinated through the Kantangren 4G controller.

  • Capacity61.44 kWh · dual-module stack
  • Voltage51.2V DC · 48V bus compatible
  • Ingress ratingIP55 · >6,000 cycles
  • ControlBMS + EMS · 4G remote access
Water · 4-in-1
SAFEBACK TK.AS.4in1 4-in-1 water quality sensor
SAFEBACK Aqua Sensor

TK.AS.4in1 · 4-in-1 Water Quality Probe

Split-body freshwater probe measuring pH / temperature / TDS / conductivity in a single unit; links to the Kantangren 4G controller over Wi-Fi 2.4 GHz via Modbus for remote reading and out-of-limit alarms; with float collar or lanyard it can be dropped straight into the pond.

  • ParameterspH / temperature / TDS / conductivity
  • AccuracypH ±0.05 · temperature ±0.1 °C
  • ConnectivityWi-Fi 2.4GHz · Modbus
  • Mountingsplit probe · float collar / lanyard / slide rail
Water · 8-in-1
SAFEBACK TK.AS.8in1 8-in-1 water quality sensor
SAFEBACK Aqua Sensor

TK.AS.8in1 · 8-in-1 Water Quality Probe

Adds ORP / specific gravity / salinity on top of the four parameters; works in seawater, brackish and fresh water — purpose-built for shrimp ponds; TDS and conductivity auto-range, with salinity covered across the full 0.01%~25.00% span.

  • ParameterspH / temperature / TDS / EC / ORP / SG / salinity
  • Rangesalinity 0.01~25% · ORP ±999 mV
  • ConnectivityWi-Fi 2.4GHz · Modbus
  • Suitable forseawater / brackish / freshwater

APPMobile App (Android / iOS)

Log in and go — no complicated setup. Multi-pond control · live dashboard · one-tap remote switching · alarm push notifications.

  • real-time DO / pH / ammonia / water temperature trends
  • centralised multi-pond management: one account for 50 ponds
  • graded alarms: app push + voice call / SMS
  • O&M mode: remote commissioning · firmware upgrade · ticket workflow

WWeb Management Console

A single management platform for distributors, integrators and enterprise accounts: full device lifecycle + customer management + financial reconciliation.

  • device records · online status · fault history
  • customer tiers · regional licensing · channel rebates
  • OTA push · staged rollout · forced upgrade
  • alarm tickets · dispatch · closure · follow-up

CCloud Platform (EMQX + TDengine + PostgreSQL)

Millions of devices, millisecond-resolution time series, built on the company's existing IoT middleware platform — negligible marginal cost.

  • device onboarding: MQTT over TLS · per-device credential
  • time-series store: TDengine · 30-day+ fast replay
  • business database: PostgreSQL · customers / orders / billing
  • rule engine: visual configuration · complex interlocks
  • API gateway: open for third-party system integration
PLATFORM UI

Platform Interfaces at a Glance

SAFEBACK® EMS energy cockpit, web farm overview and mobile app — three entry points for big-screen O&M, desktop management and mobile operation.

EMS energy management cockpit interface
EMS · Energy Cockpit

Storage / PV / Genset Dispatched on One Screen

Battery SOC, PV power, grid / genset status and load interlocks all visible on one screen; automatic peak-valley arbitrage decisions, with the full energy flow of the farm on a PC dashboard.

Kantangren web platform visual dashboard
Web · Farm Overview

pond map plus live DO trends

Centralised multi-pond management: live DO / water temperature / pH / ammonia trends, device online status, remote aerator control and alarm tickets — all in one place.

SAFEBACK mobile app interface
Mobile App · Android / iOS

SAFEBACK Mobile App

Monitor pond DO, view equipment status, receive alerts and manage aeration from your phone with the SAFEBACK app (Android / iOS).

BUSINESS VALUE

One System · Six Core Capabilities

The first overseas version focuses on the functions farm operators use every day.

01
Real-time DO
Monitor dissolved oxygen continuously.
02
Automatic Aeration
Apply configured rules to aerator control.
03
Low-Oxygen Alerts
Receive alerts when pond conditions need attention.
04
Remote Monitoring
View pond and device status from your phone.
05
Local Fallback
Configured local control can continue during connectivity loss.
06
Multi-Pond Management
Manage multiple ponds and devices in one system.
BY FARM TYPE

Find the solution for your farm type

Fish, shrimp and crab ponds fail for different reasons. Shrimp are the most oxygen-sensitive; in crab ponds, aquatic weeds consume oxygen at night; fish ponds are most at risk in muggy weather and before dawn. Pick your scenario, then see the setup and how we deploy it.

STANDARD PLANS

Three Standard Packages · Predictable Budget

From a 0.3 ha starter pond to a 6.7 ha+ enterprise operation, three packages cover most farm sizes. CNY figures converted at approx. 7.15 CNY/USD; the formal quote follows an on-site survey.

PLAN A

Starter

single pond / small farm / 1~2 aerator circuits
Investmentapprox. USD 7,000-11,000(varies with existing plant room / genset)
  • 1 × 4G controller (4 outputs)
  • 1 × fluorescence DO sensor + wiper
  • 1 × smart electrical enclosure (IP55 + four-stage lightning protection)
  • 1 × VFD (not required if the customer already runs paddlewheels)
  • Mobile App + annual cloud subscription
  • Static payback:approx. 1.5-2 years
PLAN C

Enterprise

enterprise accounts / multi-pond dispatch / Route B microgrid
Investmentapprox. USD 84,000-210,000(depends on the PV / storage / genset mix)
  • 6~12 × 4G controllers · centralised multi-pond dispatch
  • DO / pH / ammonia / water temperature · full parameter monitoring
  • PV-storage-genset microgrid (PCS + EMS + genset)
  • enterprise web edition · subsidiary tiers · regional agencies
  • premium subscription + custom reports + API integration
  • Static payback:approx. 2.5-3.5 years
DELIVERY PROCESS

Six Standard Delivery Steps · A Checklist for Every One

We do not sell "installed then ignored" hardware. From survey to acceptance, all six stages are run against standard manuals — each step has a checklist, a signature and full traceability.

STEP 1

Site Survey

Engineers come to the pond with the On-Site Survey Checklist and confirm conditions item by item.

  • supply type / availability of neutral and earth
  • three-phase voltage measurement and supply stability
  • 4G signal strength and aerator power
  • survey report plus draft design
STEP 2

System Design

Route is chosen by pond scale and budget: native DC 48V or 380V retrofit.

  • placement plan: sensors / enclosures / antenna
  • cable sizing and current-rating calculation, earthing system selection
  • preset alarm thresholds and interlock strategy
  • itemised quotation with transparent configuration differences
STEP 3

Factory Pre-Assembly

Enclosures are assembled on DIN rail and power-tested in the factory, arriving ready to install.

  • four-stage lightning SPD + RCD pre-installed
  • wire numbering sleeves / crimped terminals / tin-dipped strands
  • 48-hour factory burn-in test
  • packing and shipping per the Packing & Shipping Standard
STEP 4

Installation

Crews work to the Installation Manual — they do not need to read schematics.

  • enclosure at least 30 cm above ground, shaded and waterproof
  • power and signal in separate conduits, at least 30 cm apart
  • sensors mounted between the aerators and the feeding zone
  • common issues handled per the Site Issue Response Guide
STEP 5

On-Site Commissioning

Ten steps per the On-Site Commissioning SOP: insulation → earthing → power-up → comms → interlock.

  • insulation resistance ≥1 MΩ, earthing ≤4 Ω
  • 4G registration, account binding and mobile app setup
  • DO threshold to aerator interlock verified on site
  • four-step VFD speed control jointly commissioned
STEP 6

Acceptance & Training

Checked item by item against the Acceptance Standard & Checklist, then signed off by both parties.

  • wiring / waterproof glands / functional acceptance
  • hands-on training for farmers (user manual)
  • warranty card and support channels handed over
  • the trial application period starts
6stages
fully standardized process
8manuals
survey / installation / commissioning / acceptance
10steps
on-site commissioning SOP
1days
standard single-pond installation
7days
free trial
For distributors / integrators:the complete set of installation and acceptance manuals ships with the goods; after training, local crews can take on Kantangren projects.
AFTER-SALES SERVICE

Remote Diagnostics First · A Graded SLA Behind It

The devices report their own faults: the cloud platform monitors 24/7 and most issues are resolved remotely, without waiting for an engineer to travel out. Anything that does need a visit follows P0~P3 graded response targets.

Four Ways to Report a Fault

one of them always answers, even at midnight

  • Support hotline: answered by a human 24/7
  • WeChat support: scan to add, one-to-one
  • In-app ticketing: raise a ticket with one tap
  • Cloud auto-monitoring: offline devices or abnormal DO auto-dispatch a ticket

Remote Diagnostic Capability

12 remote capabilities — most faults fixed without leaving the village

  • live data / 30-day history replay
  • remote restart (soft reset + hard power cycle)
  • remote configuration: thresholds / alarms / cleaning interval
  • delta OTA upgrade · staged rollout
  • signal strength / supply voltage / link quality diagnostics

Spare parts & warranty

wear parts are listed at fixed prices — replace a part, not the whole unit

  • fluorescent cap every 1~2 years (approx. USD 11-21)
  • silicone cleaning brush every 6~12 months (approx. USD 1-2)
  • sensors supportfast swap of the complete assembly
  • board-level repair: the service centre swaps modules, not boards
  • regional spare-parts stock plus a standardized tool list

Ticket Grading & SLA Commitment

Pond-loss risk is always handled at the top grade — keeping the fish alive comes before everything.

GradeDefinitionFirst responseResolution timeTypical case
P0 Criticalall aerators out of control, pond-loss risk present15 minutes4 hoursdevice offline + critically low DO
P1 Severesome circuits out of control, sensor failure30 minutes24 hoursone relay channel not switching
P2 Normalabnormal data but aeration unaffected2 hours48 hoursfrequent 4G dropouts, DO jumps
P3 Minorusage questions, feature suggestions4 hours7 dayshow to set timer mode
Every ticket is traceable end to end: created → accepted → diagnosed → resolved → customer confirmed → closed → follow-up. Every ticket is archived, and response data is reviewed monthly.
BUSINESS MODEL

Hardware Tiers + Subscription Services

Hardware is the entry point; subscription is the retention. Start from the basic tier and upgrade with farm size — long-term retention has a reason behind it.

Hardware · Three Tiers

A hardware ladder from from single ponds to farm networks; configuration differences are public and transparent, upgradeable on demand.

TierHardwareSuitable for
Basicrelay modesingle pond under 0.3 ha
VFDVFD closed-loop speed controlstandard farms of 0.7-2 ha
FlagshipDC 48V + storage + microgridover 2 ha

Subscription · Four Levels

Annual subscription is priced in steps by service depth; support, O&M, data and value-added services are selectable and configurable.

LevelServiceValue
Datalive trends · history replaybasic monitoring
Alertsgraded alarms · voice-call notificationrisk backstop
O&MOTA · remote commissioning · ticketslong equipment life
Value-addedwater quality reports · feeding advice · APIbetter farm management
ROADMAP

Four Rollout Stages · No Hardware Change, Firmware Only

Start from the basic configuration and layer on capability as the customer grows. Deployed hardware is 100% compatible with the next stage of firmware. Stage 5 (Vision AI) is in R&D, requires new sensing hardware, and is currently piloted in representative ponds.

1

Stage 1

P1 · Sensors + Relays

4G controller + fluorescence DO sensor + direct-on-line relay start: the first step of "DO visibly measured + aerators switched automatically".

MVP · 1~2 months
2

Stage 2

P2 · + VFD Speed Control

Add a VFD; DO thresholds drive four interlocked speed steps, Potential savings vary by site.

Energy saving · +1~2 months
3

Stage 3

P3 · + DC 48V + Storage

New ponds adopt the native DC 48V microgrid: intrinsic safety plus greatly improved lightning withstand.

Safety · Route A
4

Stage 4

P4 · + Genset + Microgrid EMS

Existing 380V ponds can be evaluated for PV-storage-genset integration according to site conditions and load requirements.

Reliability · Route B
STAGE 5 · IN R&D

Vision AI · Let cameras watch the pond for you

Underwater cameras + an edge AI box + cloud-side decision-making. Recognised events are translated by the 4G controller into Modbus commands that drive aerators and feeders. Four capabilities, rolled out by maturity.

Surface gasping / schooling → aeration

Sudden density surge at the surface plus a sustained gasping posture. Aeration starts once DO stays below threshold for 5 minutes; if DO has not recovered 30 minutes after start-up, a second alarm fires.

Pilot
Dead-fish detection + photo evidence

Detects floating, motionless or belly-up individuals, captures photo evidence, and pushes a cloud alarm together with recommended manual action.

Ready
Growth monitoring (length / weight)

A fixed side-view camera plus image calibration estimates body length and weight. Reference accuracy: length ±5~10%, weight ±10~15%, used to manage feed ration and harvest timing.

In R&D
Smart feeding (behaviour-driven)

Judges hunger and satiety from feeding activity, competition speed and leftover feed, then adjusts the ration dynamically. Time-window accumulation avoids single-frame misjudgement.

In R&D · Phase 3

Engineering limits: Underwater imaging is constrained by turbidity, algae and biofouling, and low light. It requires an anti-fouling shroud plus an automatic cleaning mechanism (wiper / ultrasonic) and low-light or IR illumination. Edge compute should be RV1126 / HiSilicon class; ESP32 is used for capture and transmission only, not for on-device inference.

Delivery status: Stage 5 requires additional underwater sensing hardware and does not follow the "no hardware change" path. It is currently piloted in 1–2 representative ponds only and is not yet a standard deliverable. Feasibility depends on on-site water quality and pond survey.

BEYOND AQUACULTURE

From Smart Aquaculture to More Energy Scenarios

SAFEBACK is extending its intelligent sensing, control and Energy AI technology to more energy applications. Smart aquaculture is our first market — not the only one. The same self-developed sensing, control and Energy AI stack is heading for a bigger energy world.

Industrial Power

Electrical-safety monitoring, energy metering and intelligent control for factory equipment.

Commercial Buildings

Building distribution and energy management for HVAC, lighting and other loads.

Campus Energy

Site-level power supply, solar-plus-storage coordination and efficiency optimization.

Energy Storage

Storage products available as OEM/ODM with the SAFEBACK smart control system.

Solar PV

PV integration, generation monitoring and source-grid-load-storage dispatch.

EV Charging

Charger integration, managed charging and load control.

These are technology expansion directions; product form and delivery plans subject to official announcements.

SAFEBACK Kantangren

Kantangren

SAFEBACK
SAFE SMART ENERGY

We Watch Your Pond, So You Can Sleep Soundly

Kantangren is SAFEBACK's aquaculture-focused industry brand; SAFEBACK is a safe smart energy technology brand of Guangzhou Hotekey Electronics Co., Ltd.: controllers + sensors = core hardware (fully self-developed), AI + platform = core software, and storage available as OEM/ODM energy products. Smart aquaculture is our first market; industrial, commercial and storage applications are the next stage of expansion.

In the aquaculture market, the brand promise "We watch your pond, so you can sleep soundly" frees farmers from 3 a.m. patrols, the anxiety of stormy nights and the monthly power bill. Every solution has an engineering basis, every number has a source, and every function can be verified on its own.

The name SAFEBACK stands for Trust And Keep Energy-safety — the trusted choice for guarding farm energy safety: Technology at the core, Accuracy as the basis, Yield as the goal, Knowledge to simplify, Ecology for the long run, and Ease on every pond. SAFEBACK — Keep your aquaculture always powered & safe.

Brand
SAFEBACK / Kantangren
Trademark
Class 9 filed
Primary colour
#1C76F5 deep blue
Domains
kantangren.com
FAQ

Tell Us About Your Farm

Tell us about your ponds, aerators and current monitoring setup. We will recommend a suitable SAFEBACK configuration.

How long until fish suffocate after a pond power cut?

The real killer is the small hours after the outage. Once the aerators stop, dissolved oxygen falls off a cliff between 3 and 5 a.m. and a whole pond can be lost in hours. The Kantangren DC 48V storage architecture switches over the instant the grid drops and the 4G controller raises a real-time alarm - turning "wake up and find out" into "get warned in advance".
Why does dissolved oxygen crash before dawn? Read the explainer →

Why are electricity costs so high in aquaculture?

Because conventional aerators only know on/off, not dissolved oxygen - so most of the running time is wasted, and the power bill can eat a significant share of operating costs. Kantangren measures DO in real time with a fluorescence sensor and modulates the VFD on demand, with potential savings that depend on pond conditions, equipment and operating strategying.
How the VFD closed loop aerates on demand →

Do I still need to patrol the pond at night to check for gasping fish?

No. The system monitors dissolved oxygen and temperature 24/7, switches aeration on automatically when limits are exceeded, and sends voice-call / WeChat alarms, with live curves on your phone - night patrol becomes automatic system watch.
How data travels from pond to phone →

How do you deal with dissolved oxygen sensor drift and frequent maintenance?

Drift is usually not a dead probe - it is biofilm. Conventional polarographic probes need membrane replacement and cleaning every 1~3 months; switch to a fluorescence probe (no membrane, no frequent recalibration) plus an automatic wiper in an IP68 titanium-alloy housing and maintenance frequency drops by an order of magnitude.
What biofouling is, and how auto-cleaning works →

More questions? Read the full FAQ - 10 questions →

China Market · Field-first deployment

Built to watch your pond, so you can sleep soundly

SAFEBACK connects dissolved oxygen monitoring, low-oxygen alerts, aerator control and mobile visibility. It is designed around practical pond operations; final configuration depends on the farm, ponds and existing equipment.

Reduce night-patrol pressure

Monitor key ponds and receive low-oxygen alerts without relying entirely on manual night checks.

  • Mobile status viewing
  • Low-oxygen alerts
  • Historical data

Scale from one pond to many

Start with a pilot pond or farm, then expand across multiple ponds as the operating model is validated.

  • Multi-pond visibility
  • Centralized equipment status
  • Site survey and staged deployment
Free Pond Check

Share your species, pond count, pond size, aerator count and current pain points.

CONTACT US

Tell Us About Your Farm — We Will Recommend a Suitable Configuration

Tell us your farm scale and pond setup; an engineer will contact you within one business day with an on-site survey and a draft proposal.

Contact

Distributors, farm owners, integrators and enterprise accounts are all welcome. Every proposal includes an on-site survey and a trial application.

BrandSAFEBACK Kantangren
OperatorGuangzhou Hotekey Electronics Co., Ltd.
AddressRoom 101, Building B, No. 885 Shenzhou Road, Huangpu District, Guangzhou
Postal code510663
Domainswww.kantangren.com (primary domain)
Chinese brand domainkantangren.cn (registered · 301 to the main site)
Technology domaindodeep.cn (DO sensor line · registered · overseas sub-site)
Luka Sun WeChat QR code - scan to connect 1-on-1
Scan to add WeChat · 1-to-1 contact
Get a Free Pond Assessment

Tell us about your farm (~1 min). We will reply within 1 business day with:
· Equipment sizing (controllers / DO sensors / aerator channels)
· Indicative budget and payback estimate
· On-site survey arranged separately if needed

Start the assessment →
Chat on WhatsApp Email us
By submitting you agree to our Privacy Policy. We never share your information with third parties.